8 ICU Medical CADD-Solis Infusion Pump - Alarm: Pump automatically stopped

ICU Medical CADD-Solis

Alarm: Pump automatically stopped

On this page

Asset Type

Infusion Pump

Manufacturer

ICU Medical

Model

CADD-Solis

What This Guide Helps With

This guide helps troubleshoot the Pump automatically stopped alarm on an ICU Medical CADD-Solis infusion pump. The manual lists this as a high-priority alarm, meaning the pump has stopped delivery and needs immediate clinical attention before therapy is restarted.

This alarm may be related to battery status, disposable attachment, occlusion condition, reservoir volume, another active alarm, or a pump condition that requires review on the display.

Step-by-Step Troubleshooting

Ensure Patient Safety First

Check the Display for the Stop Reason

Verify Battery Status

Check the Disposable Attachment

Check for Occlusion or Flow Restriction

Verify Reservoir Volume

Review Active Alarms Before Restarting

If the Problem Persists

If battery condition, disposable attachment, occlusion status, reservoir volume, and active alarms have been checked and the pump still automatically stops, remove the infusion pump from service.

Label the pump Out of Service and send it for repair or bench evaluation. Do not return the pump to patient use until the automatic stop condition is confirmed corrected and the device passes required functional checks.

Clinical Use Tip

Never troubleshoot this alarm on an active patient if therapy safety could be affected. Move the patient to a backup pump or approved alternate delivery method first, then troubleshoot the CADD-Solis when it is safe to do so.

Work Order Documentation (CCR Method)

CCR = Complaint, Cause, Resolution

Complaint

What was reported by the clinical staff.

Example:
"ICU Medical CADD-Solis infusion pump displayed high-priority alarm: Pump automatically stopped."

Cause

What was observed during troubleshooting.

Example:
"Pump display showed automatic stop condition. Battery status, disposable attachment, occlusion status, reservoir volume, and active alarms were checked."

Resolution

What action was taken.

Example:
"Corrected external setup issue, verified alarm cleared, confirmed pump operation with clinical staff, and returned pump to service. If alarm persisted, pump was labeled Out of Service and sent for bench evaluation."

Helpful Details to Include (If Known)

Final Thought

A high-priority pump stopped alarm should always be treated as a therapy interruption first and a technical issue second. Confirm patient safety, read the display, check the simple external causes, and escalate the pump if it cannot be safely restarted.

That is successful troubleshooting.